Customization: | Available |
---|---|
Type: | Bare |
Conductor Type: | Solid |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Tankii chromel alumel 14AWG 40AWG K type thermocouple wire
NiCr-Ni(Type K) thermocouple finds the widest use in all basemetal thermocouple, at temperature above 500 °C.
Chemical Composition
|
|||||
Conductor Name |
Polarity |
Code |
Nominal Chemical Composition /% |
||
Ni |
Cr |
Si |
|||
Ni-Cr |
Positive |
KP |
90 |
10 |
-- |
Ni- Si |
Negative |
KN |
97 |
-- |
3 |
Working Temperature
|
||
Diameter/mm |
Long time Working temperature /ºC |
Short period Working temperature /ºC |
0.3 |
700 |
800 |
0.5 |
800 |
900 |
0.8,1.0 |
900 |
1000 |
1.2,1.6 |
1000 |
1100
|
2.0,2.5 |
1100 |
1200 |
3.2 |
1200 |
1300 |